Knowledge Base Technical Questions FAQ1. Questions Found. QUESTIONHow will installation of a Magnehelic gage 1. ANSWERAccuracy will not be affected, but response time will be increased in proportion to the length of the tubing. RELATED PRODUCTSSeries 2. Series 2. 00. 0 SPSeries 6. QUESTIONWhich Capsuhelic gage ports could be connected to the pressure source in liquid serviceANSWERThe bottom ports. This allows bleeding of entrapped air from the top ports to eliminate reading error due to compression of entrapped air in the gage. Bleed fittings should be installed in the top ports. RELATED PRODUCTSSeries 4. QUESTIONCan a standard Magnehelic gage be used for natural gas or propane service ANSWERNo. As the silicone diaphragm will be attacked by these gases. Artisteer Automated Web Designer. Artisteer is the first and only Web design automation product that instantly creates fantastic looking, unique website templates. Digital Download Marketplace. Its hard to believe that the year is already almost over. The leaves are beginning to change, which can only indicate one thing. Oracle acquired Sun Microsystems in 2010, and since that time Oracles hardware and software engineers have worked sidebyside to build fully integrated systems and. Download the free trial version below to get started. Doubleclick the downloaded file to install the software. Tomorrow is Lipstick Day and M. A. C. is giving away free full tubes of the stuff to celebrate. You dont have to buy anything, just show up at one of their U. S. Research Resources. A Subject Tracer Information Blog developed and created by Internet expert, author, keynote speaker and consultant Marcus P. Zillman. In a pioneering effort to control, measure and understand magnetism at the atomic level, researchers working at the. Listing of web test tools and management tools link checking, html validation, load testing, security testing, java testing, publishing control, site mapping. Full line catalog of Industrial controls including pressure gages, manometers, pressureswitches, transmitters, flowmeters, flowswitches, pitot tubes, anemometers. Now that you know what lucid dreaming is, and you know the benefits and risks, its time to give it a solid try. Get ready, oneironautswere about to take off. A Buna N diaphragm should be specified. RELATED PRODUCTSSeries 2. Series 6. 05. Series 2. SPQUESTIONWhat happens when a Magnehelic gage equipped with the low temperature option is operated below 2. Fahrenheit 2. 9 degrees Celsius ANSWERBelow that temperature the accuracy of the gage deteriorates beyond our published specification due to stiffening of the diaphragm. RELATED PRODUCTSSeries 2. Series 6. 05. Series 2. SPQUESTIONMay a standard gage be reconfigured in the field from automatic to manual resetANSWERYes. By simply making a wiring change on the relay terminal board per the information in the instruction bulletin. QUESTIONHow much may the published pressure and temperature specifications for Dwyer gages and controls be safely exceeded ANSWERPublished specifications may not be exceeded To do so will void the warranty as well as expose the customer, the stocking representative, and Dwyer Instruments to product liability action. QUESTIONIs National Institute of Standards and Technology traceability available for the Magnehelic GageANSWERNo. But Magnehelic gages can be given a special 6 point calibration check with an NIST traceable master gage and a certificate can be supplied. RELATED PRODUCTSSeries 2. Series 6. 05. Series 2. SPQUESTIONHow do I hook up my Magnehelic Gage ANSWERIn Bulletin A 2. Magnehelic to the following applications positive pressure, negative pressure, and differential pressure. RELATED PRODUCTSSeries 2. Series 6. 05. Series 2. SPQUESTIONWhat approved accessories go with the Model TDL 1. ANSWERA number of approved accessories will greatly contribute to the featureset of the Model TDL 1. Please check the corresponding product page to view the list of available accessories. RELATED PRODUCTSModel TDL 1. QUESTIONWhat approved accessories go with the Model TDL 1. ANSWERA number of approved accessories will greatly contribute to the featureset of the Model TDL 1. Please check the corresponding product page to view the list of available accessories. RELATED PRODUCTSModel TDL 1. Model SM 1. 00. QUESTIONWhy must Dwyer pressure switches be mounted with the diaphragm in the vertical plane ANSWERIn other than a vertical plane, the diaphragm can sag and cause a shift in set point or a change in the adjustable set point range. The switch may even fail to reset at the minimum set points. This is the same phenomena that causes inaccuracy in Magnehelic and Capsuhelic gages when mounted in other than a vertical position. RELATED PRODUCTSSeries 2. Series 4. 00. 0QUESTIONHow can a standard 1. Celsius ANSWERUse metal tubing for sensing lines long enough to safely dissipate the heat. RELATED PRODUCTSSeries 1. QUESTIONDoes Dwyer offer a fully ULFMCSA approved explosion proof pressure switchANSWERYes. The 1. G Series. RELATED PRODUCTSSeries 1. Series 1. 95. 0GQUESTIONCan the standard H2 pressure switch be used with water ANSWERNo. The brass or SS housing must be specified for compatibility reasons. The aluminum housing can leak into the switch. RELATED PRODUCTSSeries H2. QUESTIONWhat factor is used to correct for different flowmeter inlet pressure ANSWERIf the flowmeter is exhausting to atmosphere, no correction factor is needed. If back pressure is present due to downstream plumbing or restrictions, this error can be corrected utilizing the conversion curves in our full line catalog or the following equation. Pressure Q2 Q1 x P1 x T2P2 x T1Where Q1 Observed Flowmeter Reading. Q2 Standard Flow Corrected for Specific Gravity. P1 Actual Pressure 1. Gage PressureP2 Standard Pressure 1. T1 Actual Temperature 4. R Temp FT2 Standard Temperature 5. R, which is 7. 0F. RELATED PRODUCTSSeries RMSeries VFCVFCIISeries MMSeries VFQUESTIONWhy are top mounted valves recommended for flowmeters used for vacuum service ANSWERTo maintain atmospheric pressure in the indicating bore and therefore preserve accuracy an inlet restriction would reduce pressure in the bore. This is essentially the opposite situation to outlet back pressure in a pressure system which increases pressure in the bore and also affects accuracy. Remember that all standard Dwyer flowmeters are calibrated for standard atmospheric pressure and temperature in the bore. RELATED PRODUCTSSeries MMSeries RMQUESTIONIs the Rate Master or Visi Float Flowmeter compatible with any media ANSWERThe Rate Master Flowmeter is manufactured from a polycarbonate plastic and the Visi Float Flowmeter is manufactured from acrylic. Compatibility charts need to be reviewed to determine if these materials of construction are compatible with your media. RELATED PRODUCTSSeries VFSeries RMSeries VFCVFCIIQUESTIONAre special ranges available for the Rate Master andor Visi Float Flowmeter ANSWERYes, other ranges are available which are not specified in our catalog. Please feel free to contact Dwyer with questions on these ranges. RELATED PRODUCTSSeries VFCVFCIISeries RMSeries VFQUESTIONWhat is the key feature of both Proximity position indicators and level switches that sets these products apart from all competitors ANSWERMagnetic coupling. RELATED PRODUCTSSeries Mark. Series PLSQUESTIONHi Flow control valves call out ANSI B1. Class IV flow leakage. What does this mean ANSWERANSI B1. This specification has actually been superseded by ANSIFCI 7. Class IV. The class IV designation defines the allowable amount of leakage through the valve seat in the closed position. Class IV allows for. Cv, to pass through the seat. Class IV is common for metal to metal seated valves. RELATED PRODUCTSSeries 2. VA3. 00. 0WAQUESTIONWhat if I need parts for my Hi Flow control valve ANSWERMany Hi Flow valves have been in service for 1. However, since Hi Flow valves are commonly used in steam service, a severe application, some parts may wear over time. Unlike other control valves, Hi Flow valves are designed with removable seat rings making repair or replacement of components an option. Descargar Historia De Bolivia De Carlos Mesa Pdf File more. Although all parts are available, you will probably never need more than a seat ring, plug assembly, and stem packing to have a valve that is like new. RELATED PRODUCTSSeries 2. VA3. 00. 0WAQUESTIONWhat two basic types of position indication are provided with the Proximity position indicator ANSWERVisual mechanical and electrical. RELATED PRODUCTSSeries VPISeries QVSeries Mark. QUESTIONHow many different size housings does Proximity provide for position indicationHow many switches in a single housing ANSWERTwo sizes 2 switch and 4 switch housings. RELATED PRODUCTSSeries QVSeries Mark. QUESTIONWhat two types of continuous signal feed back can Proximity provide with the position indicator ANSWERResistive potentiometer and current transmitter. RELATED PRODUCTSSeries Mark. QUESTIONWhat are the two dry product level switch model types What ranges do they cover How are they adjusted How many set points do they have ANSWERGSD3. DA gravity elastomer suspension, aluminum housing, polyurethane diaphragm, standard 1. PSD1. 6A pneumatic fabric, suspension, aluminum housing, filter fabric diaphragm, polyester 1. They can be adjusted to any level. They are adjusted by a screw adjustment. One setpoint available.